现代纺织技术 ›› 2026, Vol. 34 ›› Issue (09): 136-144.DOI: 10.12477/j.att.202511030

• • 上一篇    

保暖服动态瓦片结构的热湿调控性能

  

  1. 北京服装学院服装艺术与工程学院 100029
  • 出版日期:2026-09-01 网络出版日期:2026-09-21
  • 基金资助:
    北京服装学院爱慕内衣研究院研发项目(HXKY05190336)

Thermal and moisture regulation performance of dynamic tile structures in thermal clothing

  1. School of Fashion, Beijing Institute of Clothing Technology, Beijing 100029, China
  • Published:2026-09-01 Online:2026-09-21

摘要: 为解决保暖服在运动状态下的热湿舒适性问题,设计了一种能够根据人体运动状态自适应调节热阻与湿阻的瓦片结构材料,该材料由底布和多个独立瓦片面料制成。 通过开展瓦片动态分析实验,结合不同状态下瓦片结构材料的热阻与湿阻测试,探究了不同活动强度下瓦片的开合规律以及其开合状态对热湿传递性的影响。 结果显示:当人体活动强度增大时,材料中瓦片的开合角度相应增加,热湿传递性能显著增 强;相较于正常行走状态,快跑状态下瓦片结构样品热阻降低 107. 54%,湿阻降低 73. 20%。 当人体处于较低活动强度或静止状态时,瓦片结构开合角度减小或完全闭合,表现出良好的保暖性能。 研究结果验证了该瓦片结构在实际应用中的可行性,实现了服装热阻与湿阻随运动强度变化的自适应调节,可为保暖服的结构创新设计提供新的思路与参考方向。

关键词: 保暖服, 瓦片结构, 热湿舒适性, 服装自主调节

Abstract: This study aims to address the issue of thermal and moisture discomfort in thermal clothing during physical activity by proposing a self-adaptive tile-structured material driven by human motion. The material consists of a fabric substrate and multiple movable tiles that open and close in response to the cyclic vertical movement of the torso. The tiles remain closed during static conditions to preserve insulation and open during movement to enhance heat dissipation and moisture permeability. Dynamic analysis using high-speed videography across five motion intensities reveals that the opening angle of the tiles increases significantly with exercise intensity, while the opening frequency is primarily determined by step rate and shows limited variation. Steady-state thermal and moisture resistance tests show that when the tiles are fully closed, the material exhibits a thermal resistance of 1.88 clo and a moisture resistance of 45.324 Pa·m²/W. As the opening angle increases and the opening cycle shortens, both thermal and moisture resistance decrease substantially. Under normal walking, thermal resistance drops by 58.93% and moisture resistance by 1.24%; under fast running, the reductions reach 107.54% and 73.20% respectively. Small-angle openings (8°, 10°) have negligible impact on moisture permeability, whereas large-angle openings significantly enhance heat and moisture transfer. The tile structure was integrated into the chest and back areas of a prototype thermal garment and evaluated through wear trials. Results show that under static conditions, the tile garment maintains comparable insulation to a conventional thermal jacket. During walking and slow running, the tile garment significantly reduces internal temperature and humidity, with average vapor pressure reductions of 11.2% and 26.3% respectively, effectively suppressing heat and moisture accumulation. This study demonstrates that the proposed motion-responsive tile structure enables adaptive regulation of thermal-moisture performance in response to varying activity levels, offering a novel design strategy for functional thermal clothing.

Key words: thermal clothing, tile structure, thermal and wet comfort, independent adjustment of clothing

中图分类号: